Sentence 9.3.1.6.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3
  6. OS1
  7. OS2
  8. OP2
  9. OH1
  10. OS3
  11. OS2
  12. OP2
  13. OS3

Objective

OP2 Structural Sufficiency of the Building

Attribution

(a) [F80-OP2.3]
(a) [F20-OP2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of:

  • insufficient compressive strength to resist expected gravity and lateral loads, or
  • the excessive shrinkage, cracking and premature failure of concrete.

This is to limit the probability of compromised structural integrity, which could lead to:

  • structural failure,
  • where concrete supports or is used in an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements, which could lead to further compromised structural integrity, or
  • where concrete supports walls or floors, an inability to resist expected loads, which could lead to
    • the excessive deformation or deflection of walls, or
    • the excessive deflection or vibration of floors.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of windows and doors, and
  • damage to the building.
Top of Page