Sentence 9.3.1.6.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3
  6. OS1
  7. OS2
  8. OP2
  9. OH1
  10. OS3
  11. OS2
  12. OP2
  13. OS3

Objective

OS1 Fire Safety

Attribution

(a) [F20,F21,F80-OS1.1]Applies where concrete supports or is used in chimneys or fireplaces.

Intent

Intent 1:

To limit the probability of insufficient compressive strength to resist expected gravity and lateral loads.

Where concrete supports or is used in chimneys or fireplaces, this is to limit the probability of the compromised integrity of the chimney or fireplace, which could lead to the ignition of combustible building components.

This is to limit the probability of harm to persons.